What is intrinsic safety?

Intrinsic safety is a way of designing electrical equipment so that it can’t release enough energy, as a spark or as heat, to ignite the gas or dust around it.

How it works

An explosion needs three things: a flammable gas or dust, oxygen, and a source of ignition. In a hazardous area the first two are a fact of the site. Intrinsic safety removes the third, by limiting the voltage, current and stored energy in the circuit so that even when a fault occurs the device stays below the ignition energy of the atmosphere.

That is why an intrinsically safe phone can be carried, charged elsewhere and used normally, rather than sealed in a heavy enclosure.

Protection levels: ia, ib and ic

The letters after “Ex i” say how many faults the design tolerates, and so which zones it may enter.

Intrinsic safety levels
iaSafe with two faults · Zone 0, 1, 2
ibSafe with one fault · Zone 1, 2
icSafe in normal operation · Zone 2

Zones and equipment protection levels

Sites are classified by how often an explosive atmosphere is present. Each zone accepts equipment of a matching protection level (EPL).

Gas
Zone 0Present continuously · EPL Ga
Zone 1Likely in normal operation · EPL Gb
Zone 2Unlikely, short periods · EPL Gc
Dust
Zone 20Present continuously · EPL Da
Zone 21Likely in normal operation · EPL Db
Zone 22Unlikely, short periods · EPL Dc

Reading an Ex marking

Here is a typical marking for a handheld device certified for Zone 1 gas, decoded segment by segment.

Ex markingExample
Gas
IIGroupSurface industry2GCategoryZone 1 gasExExplosionprotectedibProtectionIntrinsic safety, 1 faultIICGas groupHydrogen, acetyleneT4TemperatureMax 135 °CGbEPLGas, high

Choosing a device

Start from your site’s area classification drawing. Match the zone, gas group and temperature class to the device, and ask for the certificate evidence before purchase.

This guide is a summary

It doesn’t replace EN IEC 60079 or your site’s DSEAR / ATEX assessment. Always follow your competent person’s area classification.